Title:
Standard operating procedure for spot test of sulphide
Purpose:
Spot test of sulphide to confirm it's presence or absence in the sample
Scope:
This is applicable to the samples received for the testing of sulphide
Roles and responsibilities:.
Lab analyst: Testing the samples and maintain the record
Lab Manager: Ensure the QA and QC, providing the traini.l
Equipment:;.
1) Beaker 100ml
2) watch glass
Reagent:
Lead acetate solution 10% : Dissolved 10 grams of lead acetate into distilled water and makeup to 100 Ml
Health and Safety:
1) wear hand gloves, mask and goggles
Reference;
Apha method
Procedure:
1) Take waste into a break or watch glass
2) Add some distilled water over the waste to make it wet
3) Add 10 % lead acetate solution if black precipitate absorbed sulfide is present
Quality control
Blank: Test black sample using distilled water